Removing - Refitting: Oxygen sensor (ES9A)
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. It is strictly prohibited to use solvents or contact greases for cleaning the connectors of the upstream and downstream oxygen sensors.
ESSENTIAL: If raising the vehicle on a lift, wheels hanging, remove the cap of the LDS fluid reservoir. Refit the cap of the LDS fluid reservoir, once you have lowered the vehicle.
ESSENTIAL: Before carrying out any work on the exhaust system, wait for it to cool down.
CAUTION: After the ignition has been switched off: Wait 15 minutes before disconnecting the ancillaries battery so as to guarantee that the initialisations of the various ECUs are memorised.
Remove the ancillaries battery style cover.
Disconnect the ancillaries battery.
1. Recommended tools
[1] slit socket 22 mm 4386-T.
2. Oxygen sensors (front)
2.1. Location
(1) Upstream oxygen sensor.
(2) Downstream oxygen sensor.
2.2. Removing: Upstream oxygen sensor
Remove:
- The engine cover (top)
- The protective panel under the engine
Disconnect the connector of the upstream oxygen sensor (at "a").
Unclip the connector of the sensor from its support (at "b").
Remove the sensor (1); Using tool [1].
2.3. Refitting: Upstream oxygen sensor
Refit: The sensor (1); Tighten to 4,7 ± 0,7 daN.m; Using tool [1].
Clip the connector of the sensor on to its support (at "b").
Connect the upstream oxygen sensor connector (at "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
2.4. Removing: Downstream oxygen sensor
Disconnect the downstream oxygen sensor connector (at "c").
Unclip the connector of the sensor from its support (at "d").
Remove the sensor (2); Using tool [1].
2.5. Refitting: Downstream oxygen sensor
Refit: The sensor (2); Tighten to 4,7 ± 0,7 daN.m; Using tool [1].
Clip the connector of the sensor on to its support (at "d").
Connect the downstream oxygen sensor connector (at "c").
3. Oxygen sensors (rear)
3.1. Location
(3) Upstream oxygen sensor.
(4) Downstream oxygen sensor.
3.2. Removing: Upstream oxygen sensor
Remove:
- The engine cover (top)
- The protective panel under the engine
Disconnect the connector of the upstream oxygen sensor (at "e").
Unclip the connector of the sensor from its support (at "f").
Unclip: The harness (at "g").
Remove the sensor (3); Using tool [1].
3.3. Refitting: Upstream oxygen sensor
Refit: The sensor (3); Tighten to 4,7 ± 0,7 daN.m; Using tool [1].
Clip: The harness (at "g").
Clip the connector of the sensor on to its support (at "f").
Connect the upstream oxygen sensor connector (at "e").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
3.4. Removing: Downstream oxygen sensor
Disconnect the downstream oxygen sensor connector (at "h").
Unclip the connector of the sensor from its support (at "j").
Unclip: The harness (at "k").
Remove the sensor (4); Using tool [1].
3.5. Refitting: Downstream oxygen sensor
Refit: The sensor (4); Tighten to 4,7 ± 0,7 daN.m; Using tool [1].
Clip: The harness (at "k").
Clip the connector of the sensor on to its support (at "j").
Connect the downstream oxygen sensor connector (at "h").
Refit:
- The protective panel under the engine
- The engine cover (top)
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Parts & tools for this job For 2008 Citroën C5
- PARTOxygen sensorSearch: Citroën C5 2008 oxygen sensor
- TOOLOxygen sensor socketSearch: oxygen sensor socket
- TOOLOBD2 scannerSearch: OBD2 scanner