Removing - Refitting: Exhaust manifold/catalytic converter assembly
- Make
- Citroën
- Model
- C5 (X7) Factory Workshop Manual
- Year
- 2008–2017
- Section
- Exhaust › Removing - Refitting: Exhaust manifold/catalytic converter assembly
Removing - Refitting: Exhaust manifold/catalytic converter assembly
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
| Tools | Reference | Designation |
|---|---|---|
| [0193-B] | Pliers for removing exhaust clips |
| [4386-T] | slit socket 22 mm |
2. Removing
CAUTION: Protect the radiator while carrying out the work to prevent any fouling when removing the heat shields and the exhaust manifold.
CAUTION: Wait at least one hour before carrying out any work on the exhaust line.
Lift and support the vehicle.
Disconnect the ancillaries battery.
Remove the under engine protection.
Remove:
- The bolts (2)
- The upper heat shield (1)
Unplug:
- The connector of the downstream oxygen sensor (at "a")
- The upstream oxygen sensor connector (at "b")
Release the electrical harnesses of the oxygen sensors (at "c").
Remove; Using tool [4386-T]:
- The upstream oxygen sensor (3)
- The downstream oxygen sensor (4)
Remove:
- The bolts (6)
- The front heat shield (5), and extract it from underneath
- The clip (7); Using tool [0193-B]
- The exhaust front flexible pipe
Remove:
- The nuts (8)
- The lower fixings (10)
- The exhaust manifold/catalytic converter assembly (9) (from above)
- The exhaust manifold/catalytic converter assembly seal (11) (Heat shield)
3. Refitting
CAUTION: Adhere to the tightening torques.
CAUTION: Adhere to the tightening torques.
CAUTION: Always replace the seal (11) (Heat shield).
Refit:
- The exhaust manifold/catalytic converter assembly seal (11) (Heat shield) (new)
- The exhaust manifold/catalytic converter assembly (9) (from above)
- The nuts (8)
- The lower fixings (10)
- The exhaust front flexible pipe
- The clip (7); Using tool [0193-B]
- The front heat shield (5)
- The bolts (6)
- The downstream oxygen sensor (4); Using tool [4386-T]
- The upstream oxygen sensor (3); Using tool [4386-T]
Secure the electrical harnesses of the oxygen sensors (at "c").
Connect:
- The connector of the downstream oxygen sensor (at "a")
- The upstream oxygen sensor connector (at "b")
Refit:
- The upper heat shield (1)
- The bolts (2)
- The protective panel under the engine
Remove the protection from the cooling radiator.
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
Check the absence of leaks.