Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Wiring harnesses23 Instruments and warning lamps24 Locking, alarm and airbags25 Electrical - driver assistance systems26 Heating, air conditioning and audio
Citroën C6 Factory Workshop Manual (2005-2012)06 · Brakes
06 · Brakes

Removing - refitting: Vacuum pump (DT20C)

Make
Citroën
Model
C6 Factory Workshop Manual
Year
2005–2012
Section
Brake servo › Removing - refitting: Vacuum pump (DT20C)
BrakesRemoving - refitting: Vacuum pump (DT20C)

Removing - refitting: Vacuum pump (DT20C)

Citroën C6 · Removal-fitting · Ref. B3FG016EP0

Applies to: 3.0 HDI particle emission filter

ESSENTIAL: Observe the safety and cleanliness recommendations.

CAUTION: If raising the vehicle on a lift, wheels hanging, remove the cap of the LDS fluid reservoir. Refit the cap of the LDS fluid reservoir, once you have lowered the vehicle.

1. Removing

CAUTION: Before disconnecting the battery, Keep the luggage compartment lid open.

CAUTION: Before disconnecting the battery, Open the door windows slightly.

Lift and support the vehicle with front wheels suspended.

Disconnect the battery.

Remove the engine style cover.

Figure b1bg0gad

Unclip: The harnesses attaching to the air filter housing (2).

Remove the 2 nuts (3).

Disconnect and move aside the connectors (as "a").

Detach and move aside: The tubes (as "b").

Uncouple the air ducts (1).

Raise and move aside the air filter housing (2).

Uncouple: The air inlet duct.

Remove the air filter housing (2).

Figure b1jg031d

Remove the under engine protection.

Unscrew: The exhaust clip (4).

Figure b1cg01fd

Remove:

  • The bolt (7)
  • The nut (6)

Move aside the air duct (5).

Unclip: The vacuum unions (as "c", "d").

Figure b1cg01gd

Move aside the clip (8).

Remove the mountings (9).

Unclip: The harness attaching to the oil vapour resuction pipe (10).

Move aside the oil vapour resuction pipe (10).

Remove:

  • The mountings (12)
  • The air filter housing support (11)
Figure b1cg01hd

Remove the bolts (13).

Slightly move aside: The cooling duct (14).

Figure b3fg0ged

Remove:

  • The nut (16)
  • The stud (17)
  • The bolts (18)
  • The bracket (15)
Figure b3fg0gfd

Remove the exhauster (19).

2. Refitting

CAUTION: Adhere to the tightening torques.

Tightening torques:

Figure b3fg0ggd

CAUTION: On each removal: Always replace the seal (20).

Clean the joint faces.

Refit:

  • The vacuum pump (19)
  • The bracket (15)
  • The bolts (18)
  • The stud (17)
  • The nut (16)
  • The bolts (13)
  • The air filter housing support (11)
  • The mountings (12)

Position:

  • The oil vapour re-induction pipe (10)
  • The clip (8)

Refit the fasteners (9).

Clip in place: The harness attaching to the oil vapour resuction pipe (10).

Position: The air duct (5).

Relocate:

  • The (7) bolt
  • The nut (6)

Clip: The vacuum unions (as "c", "d").

Position: The air filter (2) box.

Couple up: The air inlet duct.

Refit the air filter housing (2).

Couple the air ducts (1).

Fit the nuts (3).

Secure the harnesses connecting to the air filter housing (2).

Reconnect the connectors (as "a").

Couple up the pipes (as "b").

Tighten: The exhaust clip (4).

Relocate:

  • The protective panel under the engine
  • The engine cover
  • The vehicle to its wheels

Reconnect the battery.

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Parts & tools for this job For 2005 Citroën C6