01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Interior trim20 Electrical - general21 Starting and charging22 Wiring harnesses23 Instruments and warning lamps24 Locking, alarm and airbags25 Electrical - driver assistance systems26 Heating, air conditioning and audio
Citroën C6 Factory Workshop Manual (2005-2012)01 · Engine
01 · Engine

Refilling: Additive tank

Make
Citroën
Model
C6 Factory Workshop Manual
Year
2005–2012
Section
Air and fuel supply › Refilling: Additive tank
EngineRefilling: Additive tank

Refilling: Additive tank

Citroën C6 · Draining - filling - bleeding · Ref. B1KI08P0

Applies to: 2.7 HDi particle emission filter

ESSENTIAL: Observe the safety and cleanliness recommendations.

CAUTION: Before disconnecting the ancillaries battery, Open the door windows slightly.

ESSENTIAL: If raising the vehicle on a lift, wheels hanging, remove the cap of the LDS fluid reservoir. Refit the cap of the LDS fluid reservoir, once you have lowered the vehicle.

1. Recommended tools

Additive tank filling kit.

2. Refilling

ESSENTIAL: Respect the safety and cleanliness recommendations that are specific to high pressure diesel injection (HDi) engines.

ESSENTIAL: For all work on the additive circuit, wear safety goggles and hydrocarbon resistant gloves.

Put the vehicle on a hoist.

Remove the heat shield.

CAUTION: Keep the luggage compartment lid open.

Disconnect the ancillaries battery.

Figure b1ki00md

Uncouple the pipe (1)   (at "a").

Couple the additive container to the tube (1) using the adaptor and pipe (with tap) from the filling kit.

Figure b1ki00nd

Screw on the filler union on the additive container (2)   (at "c").

Place the additive container on a component lift (2).

Open the valve located on the filler union   (at "b").

Tilt the additive container (2)   (to assist completion of filling).

Close the tap   (at "b").

Remove:

  • The filler union
  • The pipe (3)

Connect the pipe (1)   (at "a").

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.

CAUTION: Prime the fuel additive circuit; Using the diagnostic tool.

CAUTION: Reset the diesel additive ECU counter to zero.

3. Recommendations for cleanliness

ESSENTIAL: The filling kit should be recycled after the repair. Any container of "Eolys" additive that has been opened should not be kept.