Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën C8 Factory Workshop Manual (2002-2014)08 · Body - rear section
08 · Body & interior

After-sales operations: Door management

Make
Citroën
Model
C8 Factory Workshop Manual
Year
2002–2014
Section
Lock › After-sales operations: Door management
Body - rear sectionAfter-sales operations: Door management

After-sales operations: Door management

Citroën C8 · Repair procedure · Ref. D4EM1WP0

Applies to: all versions

1. Precaution

Before carrying out any diagnosis, it is essential to ensure that the contacts on the edge of the sliding door are clean.

When closing the sliding door, the sliding door module needs information that passes through the contacts on the edge of the sliding doors.

If the contacts are not clean enough, the information does not reach the sliding door module.

CAUTION: Clean the fixed contacters on the edge of the sliding door before carrying out diagnosis.

2. Initialisation of the sliding doors

The sliding doors must be reinitilaised after working on the following:

  • Engine removal
  • Removal of a sliding door
  • Battery disconnection

To initialise the sliding doors, effect a motorised opening, a motorised closing and a motorised opening.

The initialisation of the sliding doors is independent for each door and must be carried out on both doors.

Manual opening or closing of the doors does not create a need for reinitilaisation of the sliding doors.

N.B.: If the battery has been disconnected, the sliding side doors have to be re-initialised.

3. Drive cable tension

The drive cables must be slackened in order to disconnect the cables and the trolley fixed on the door.

The cables are slackened by acting on the hub of the cable drum.

The drive cables must be retensioned manually after refitting a sliding door or drive motor.

The cables are tensioned by acting on the hub of the cable drum.

4. Reading fault codes

The following faults can be read using the diagnostic tool:

  • Treatment unit fault
  • Left door initialisation fault
  • Right door initialisation fault
  • Supply voltage outside limits
  • Vehicle speed information invalid
  • Supply to sliding door position sensors
  • Left hand push button fault
  • Rear left button
  • Fault on left hand position sensor n° 1
  • Fault on left hand position sensor n° 2
  • Right hand front push button
  • Right hand rear push button fault
  • Fault on right hand lock with integral switch
  • Fault on right hand position sensor n° 1
  • Fault on right hand position sensor n° 2
  • Left door actuator output fault
  • Left engine output fault
  • Left brake output fault
  • Right door actuator output fault
  • Right engine output fault
  • Right brake output fault

5. Reading of the parameters

The following parameters can be read using the diagnostic tool:

  • Front left button: Inactive / active
  • Rear left button: Inactive / active
  • LH lock with integrated switch: Inactive / active
  • Left hand motor output: Inactive / active
  • Brake output: Inactive / active
  • Left hand door motor: Inactive / active
  • Left hand position sensor supply: Inactive / active
  • Front right button: Inactive / active
  • Rear right button: Inactive / active
  • Right hand lock with integral switch: Inactive / active
  • Right hand door motor output: Inactive / active
  • Brake output: Inactive / active
  • Right hand door motor: Inactive / active
  • Right hand position sensor supply: Inactive / active

6. ACTUATOR TESTS

The following actuator tests can be performed with the help of the diagnostic tool:

  • Left hand door control
  • Left hand lock motor
  • Right hand door control
  • Right hand lock motor
  • Door opening/closing sound emission
  • Safety auto-reverse triggering sound emission
  • Operating fault sound emission

7. Configuration

It is not possible to download to the sliding door control unit.

8. Back-up modes

8.1. Fault on locks with integral switches

8.1.1. Lock with integral switch in open circuit

Manual opening of the sliding doors is only possible using the exterior or interior opening switches.

If the fault appears during motorised closing of the door, the anti-pinch intervenes and the door can only be closed manually.

8.1.2. Lock with integral switch in short circuit

The electric controls of the door with fault are deactivated. Opening and closing can only be done manually. An audible beep is produced for each command that is not carried out.

8.2. Push button fault

8.2.1. Push button in open circuit

No action is possible.

8.2.2. Push button in short circuit

Deactivation of push-button with fault. Manual opening and closing of the door is possible.

8.3. Position sensor

8.3.1. Position sensor fault

The electric controls of the door with fault are deactivated. Manual opening and closing of the door is possible. An audible beep is produced for each command that is not carried out.

8.3.2. No information from position sensor

If the loss of information occurs during motorised movement of the door, the anti-pinch intervenes and door opening and closing can only be done manually. An audible beep is produced for each command that is not carried out.

8.4. Lock opening motor fault

The electric controls of the door with fault are deactivated. Manual opening and closing of the door is possible. An audible beep is produced for each command that is not carried out.

8.5. Clutch fault

The electric controls of the door with fault are deactivated. Manual opening and closing of the door is possible. An audible beep is produced for each command that is not carried out.

8.6. Sliding side door motor fault

The electric controls of the door with fault are deactivated. Manual opening and closing of the door is possible. An audible beep is produced for each command that is not carried out.

8.7. Vehicle speed data fault

If the vehicle speed information is not valid, the module considers that the speed of the vehicle is above 5 kph.

8.8. Supply voltage outside limits fault

The electric controls are deactivated. The movement of the sliding door starts and is followed to the end of its travel. The return within limits of the supply voltage reactivates the electric controls. An audible beep is produced for each command that is not carried out.

8.9. Fault on the position of the opening mechanical stop

If the module detects movement beyond the opening mechanical stop, it restarts the learning process of the stop at the next electric opening of the door. A permanant fault is recorded until the next initialisation.

Parts & tools for this job For 2002 Citroën C8

As an Amazon Associate we earn from qualifying purchases.