Removing - refitting: vacuum pump (DW10UTED4/DW10BTED4)
- Make
- Citroën
- Model
- C8 Factory Workshop Manual
- Year
- 2002–2014
- Section
- Brake servo › Removing - refitting: vacuum pump (DW10UTED4/DW10BTED4)
Removing - refitting: vacuum pump (DW10UTED4/DW10BTED4)
1. Removing
CAUTION: After switching off the ignition: wait 15 minutes before disconnecting the battery, to ensure that the initialisations of the various ECUs are memorised.
Disconnect the battery.
Disconnect the air flow meter.
Remove:
- The pollen filter and its bracket
- The air cleaner
- The air flow meter
- The air inlet duct
Relase and move aside the hoses relating to the vacuum pump.
Detach the vacuum pipe (at "a").
Remove:
- The bolts (2)
- The vacuum pump (1)
2. Refitting
Clean the joint faces.
Fit new o-rings.
Refit:
- The vacuum pump (1)
- The bolts (2); Tighten to 0,9 ± 0,1 daN.m
Attach the vacuum pipe (at "a").
Clip the pipes attached to the vacuum pump.
Refit:
- The air inlet duct
- The air flow meter
- The air cleaner
- The pollen filter and its bracket
Reconnect the air flow meter.
Reconnect the battery.
Parts & tools for this job For 2002 Citroën C8
- PARTBrake padsSearch: Citroën C8 2002 brake pads
- TOOLBrake bleeder kitSearch: one man brake bleeder kit
- FLUIDBrake fluidSearch: brake fluid
As an Amazon Associate we earn from qualifying purchases.