Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Rear seats19 Electrical - general20 Starting and charging21 Wiring harnesses22 Instruments and warning lamps23 Locking, alarm and airbags24 Electrical - driver assistance systems25 Heating, air conditioning and audio
Citroën C8 Factory Workshop Manual (2002-2014)01 · Engine
01 · Engine

Removing - Refitting: Inlet air metering unit

Make
Citroën
Model
C8 Factory Workshop Manual
Year
2002–2014
Section
Cylinder head › Removing - Refitting: Inlet air metering unit
EngineRemoving - Refitting: Inlet air metering unit

Removing - Refitting: Inlet air metering unit

Citroën C8 · Removal-fitting · Ref. B1HG01RWP0

Applies to: 2.0 HDi 163 PEF or 2.0 HDi 136 (DW10CB FAP dtr)

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Removing

Disconnect the ancillaries battery.

Remove:

  • The engine cover
  • The cooling fans control relay unit
Figure b1bg22kd

"A": Single metering unit.

"B": Double mixer.

CAUTION: Protect the engine cooling radiator to prevent damage to the fins.

Unplug; Using a thin screwdriver:

  • The inlet air mixer sensors   (at "a")
  • The inlet air pressure/temperature sensor   (at "b")

Release and move aside the electrical harness (1).

Uncouple connection (2).

Figure b1hg07wd

Disconnect the pipes (3)   (at "c").

Unclip the pipes (3).

Figure b1hg161d

Slacken the mountings (4) sufficiently to allow lateral movement of the support (5).

Figure b1hg165d

Remove:

  • The bolts (6)
  • The bolts (7)
  • The inlet air metering unit (8)

2. Refitting

CAUTION: Adhere to the tightening torques.

Figure b1hg166d

CAUTION: Check the condition of the seal (9); Exchange it if necessary.

Position:

  • The seal (9) on the inlet air mixer unit (8)
  • The inlet air metering unit (8)

Tightening procedure: Assembly of inlet air mixer control unit (8) and its mounting (5):

  • Tighten the mountings (4) by hand; The support (5) must be properly seated, allowing lateral movement
  • Tighten the bolts (7) to torque
  • Tighten the bolts (6) to torque
  • Tighten the mountings (4) to the specified torque

Couple up:

  • The vacuum pipes (3)   (at "c")
  • The inlet air union (2)

Clip in place:

  • The vacuum pipes (3)
  • The electrical harness (1)

Connect:

  • The inlet air mixer sensors   (at "a")
  • The inlet air pressure/temperature sensor   (at "b")

CAUTION: Remove the protection on the cooling radiator.

Refit:

  • The cooling fans control relay unit
  • The engine style cover

CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.

Reconnect the ancillaries battery.