ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Removing
Disconnect the ancillaries battery.
Disconnect the connector (at "a").
Disconnect the pipes (at "b").
Remove the air conduit (1).
Remove:
- The (2) bolt
- The air ducts (3)
Uncouple connection (4).
Unclip the electrical harness (at "c", "d").
Remove the bolts (6).
Slacken the bolt (7).
Tilt the support bracket (at "e").
Move aside the vacuum pump (5).
Remove:
- The (8) bolt
- The tube (9)
- The vacuum pump (5)
2. Refitting
CAUTION: Adhere to the tightening torques.
Tightening torques Engine.
Tightening torques Engine.
CAUTION: Systematically replace the seal (10).
Clean the joint faces.
Refit:
- The tube (9)
- The (8) bolt
- The vacuum pump (5) (with a new seal (10))
Install support bracket (at "e").
Refit the bolts (6).
Tighten the bolt (7).
Connect the union (4).
Clip the electrical harness (at "c", "d").
Refit:
- The air ducts (3)
- The (2) bolt
- The air duct (1)
Join the hoses (at "b").
Connect the connector (at "a").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.