Check: CNG components
- Make
- Citroën
- Model
- Jumper Factory Workshop Manual
- Year
- 1994–2002
- Section
- Air and fuel supply › Check: CNG components
Check: CNG components
ESSENTIAL: Observe the safety requirements that apply to repairs on CNG circuits (see the relevant operation).
1. Recommended tools
[1] leak detector FRAMET DF9.
[2] leak detector GAS 100.2.
2. CNG pressure sensor
N.B.: The electrical check is carried out using a shunt (2) to be placed between the CNG pressure sensor (1) and its connector (3). The output signal is registered using a multimeter on the terminal "a".
Start the engine.
Change to CNG mode.
Close the CNG tank manual safety valve.
Wait until the vehicle has switched to petrol mode then switch off the ignition.
Position the shunt.
Measure the output voltage: The voltage should be 500 mV.
The table indicates the relation between the pressure and the output voltage.
N.B.: To measure the voltage which corresponds to the pressure in the tank, open the CNG tank manual safety valve.
3. Temperature sensor
The graph indicates the variation in the resistance in relation to the temperature.
Measure the resistance between terminals "b" and "c" using an ohmmeter and disconnecting the temperature sensor (4) connector.
4. CNG injectors
Measure the resistance between terminals "e" and "d" using an ohmmeter and disconnecting the connector.
The resistance value should be 4,6 Ohm.
5. CNG pressure filter
N.B.: The pressure is checked using a 3-way union part number 1870685000 and a pressure gauge part number 4601-T.F1, graduated up to 16 bars.
Close the CNG tank manual safety valve.
Start the engine.
Change to CNG mode.
Wait until the vehicle has switched to petrol mode then switch off the ignition.
Place the connector (6) fitted with the manometer between the pipes (7) and the pressure relief valve outlet (5).
CAUTION: A little gas may escape into the atmosphere if the piping is still pressurised.
Open the manual safety valve on the CNG tank.
Run the engine in CNG mode and measure the pressure.
The pressure measured should be 9 ± 1 bars.
If the pressure is lower check:
- That there are no leaks using the tools [1] or [2]
- The high pressure using the diagnostic equipment
Parts & tools for this job For 1994 Citroën Jumper
- PARTEngine gasket setSearch: Citroën Jumper 1994 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.