Removing: Additional heating unit (WEBASTO equipment)
- Make
- Citroën
- Model
- Jumper Factory Workshop Manual
- Year
- 1994–2002
- Section
- Cooling system › Removing: Additional heating unit (WEBASTO equipment)
Removing: Additional heating unit (WEBASTO equipment)
1. Additional heating unit
Disconnect the battery negative terminal.
Put the vehicle on a hoist.
Disconnect the exhaust pipe from the clamp (1).
Disconnect the connector (2).
Drain the coolant through the 2 connectors (3): Be prepared for the flow of fluid.
CAUTION: Quickly insert a plug into the pipes (engine side).
Disconnect the fuel supply pipe from the clamp (4): Be prepared for the flow of fluid.
CAUTION: Quickly insert a plug into the pipe (engine side).
Remove:
- The 6 bolts (5)
- The support
Remove:
- The clip (6)
- The bolts (7)
- The additional heating unit
Complete assembly WEBASTO.
2. Fuel metering pump
Disconnect the battery negative terminal.
Put the vehicle on a hoist.
Disconnect the connector (8).
Disconnect the fuel inlet pipe from the clamp (9): Be prepared for the flow of fluid.
CAUTION: Quickly insert a plug into the pipe (engine side).
Remove:
- The (10) bolt
- The metering pump
Parts & tools for this job For 1994 Citroën Jumper
- TOOLA/C manifold gauge setSearch: AC manifold gauge set
- TOOLUV leak detection kitSearch: AC UV leak detection kit
- PARTCabin filterSearch: Citroën Jumper 1994 cabin filter
As an Amazon Associate we earn from qualifying purchases.