Removing - refitting: Electrical components
ESSENTIAL: Observe the safety requirements that apply to repairs on CNG circuits (see the relevant operation).
1. Recommended tools
[1] leak detector FRAMET DF9.
[2] leak detector GAS 100.2.
2. Pressure sensor
2.1. Removing
Disconnect the connector (1).
Unscrew the natural gas pressure sensor (2).
2.2. Refitting
Refit in the reverse order to removal.
3. Temperature sensor
3.1. Removing
Remove the pressure sensor (2) (see the relevant operations).
Disconnect the connector (3).
Unscrew the temperature sensor (4).
3.2. Refitting
Refit in the reverse order to removal.
4. Engine phase sensor
4.1. Removing
Disconnect the connectors (5) and (7).
Unscrew the 2 screws (6).
Remove the engine phase sensor (8).
4.2. Refitting
Refit in the reverse order to removal.
ESSENTIAL: Enter the lugs "a" of the engine phase sensor "8" into the grooves "b" of the camshaft "9".
5. Petrol injection emulator
5.1. Removing
Remove the air filter and its housing.
Unplug:
- The connector (11) (pull back its cover)
- The connector (12)
Remove the screw (10) and the petrol injection emulator.
5.2. Refitting
Refit in the reverse order to removal.
6. CNG injectors
6.1. Removing
Disconnect the connectors (13).
Remove:
- The clips (14)
- The pipes (15)
Unscrew the screws ((16)).
Remove the CNG injectors (17).
6.2. Refitting
N.B.: Check that the seals on the natural gas injectors (17) are in a satisfactory condition. Position the CNG injectors (17) according to their numbering.
Refit in the reverse order to removal.
Start the engine, change to CNG mode and check the sealing of the pipes (15) using tools [1] or [2].
7. Supply electrovalve
7.1. Removing
Disconnect the connectors (18).
Remove bolts (19).
N.B.: A little gas may escape into the atmosphere if the piping is still pressurised.
Remove the supply electrovalve (20).
7.2. Refitting
Refit in the reverse order to removal.
Start the engine, change to CNG mode and check the sealing of the pipes (19) using bolts [1] or [2].
8. CNG ECU
8.1. Removing
Remove:
- The bolts (21)
- The coating(22)
Disconnect the connectors (24).
Remove the bolts (23).
Remove the CNG injection ECU (25).
8.2. Refitting
Refit in the reverse order to removal.
Check that the vehicle operates correctly in CNG mode.