01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Electrical - general19 Starting and charging20 Locking, alarm and airbags21 Electrical - driver assistance systems22 Heating, air conditioning and audio
Citroën Jumper Factory Workshop Manual (1994-2002)01 · Engine
01 · Engine

Data - Identification: Exhaust gas recirculation circuit (XUD9)

Make
Citroën
Model
Jumper Factory Workshop Manual
Year
1994–2002
Section
Exhaust › Data - Identification: Exhaust gas recirculation circuit (XUD9)
EngineData - Identification: Exhaust gas recirculation circuit (XUD9)

Data - Identification: Exhaust gas recirculation circuit (XUD9)

Citroën Jumper · Data - identification · Ref. B1HB2UP0

Applies to: 1.9 d

In order to meet the emission standard X3, the DHX engines are equipped with an exhaust gas recycling system, known as "EGR".

1. Principles of operation

The EGR exhaust gas recycling system reduces the quantity of nitrogen oxide (N0x) in the exhaust gases.

This reduction is obtained by recycling part of the exhaust gases in the inlet duct.

The conditions for the recycling are a function of the engine water temperature and load.

Figure b1hp07vd

1.1. Composition

(1) Air cleaner.

(2) Load switch.

(3) temperature switch 60°C.

(4) Exhaust.

(5) Recycling valve.

(6) vacuum pump.

(7) Solenoid valve EGR.

1.2. Location

The load switch is fitted to the injection pump.

The thermal switch is fitted to the water outlet housing (2-way green connector).

The recycling valve is mounted on the exhaust manifold.

The vacuum pump is situated on camshaft end.

The EGR electrovalve pilots the EGR valve.

EGR valve (5) is operated by vacuum pump (6) when electrovalve (7) is activated.

Electrovalve (7) is activated when:

  • Engine running
  • A coolant temperature above 60 °C
  • The engine load is inferior to the limit indicated by injection pump load switch (2)

2. Data - Recycling valve

makeReferencesColour identificationFlow at 600 mbars
PURFLUXGR 54yellow18-22 m3/h

Parts & tools for this job For 1994 Citroën Jumper