Check: Pre-heating system
- Make
- Citroën
- Model
- Jumper Factory Workshop Manual
- Year
- 1994–2002
- Section
- Pre-heating › Check: Pre-heating system
Starting and chargingCheck: Pre-heating system
Check: Pre-heating system
1. Principles of operation
On switching on the ignition, the plugs and instrument panel warning lamp are supplied by the pre-heater control unit.
The supply to the pre-heater plugs is maintained when the warning lamp goes out (timed period depending on the ambient temperature).
The pre-heater plugs are supplied during the starting phase. Their supply will be interrupted as soon as the engine is running.
2. Pre-heating system
3. Checking the pre-heating function
Preliminary check: Battery voltage U Superior or equal to 12,5V.
| Input | ||||
| Check: U1 ð U (battery voltage) | No OK | Verify: The continuity of the supply leads | ||
| Yes | ||||
| Switch on the ignition. As soon as the ignition is on, the pre-heater warning lamp lights up; it goes out after the pre-heating time (duration) | No OK | Exchange: The pre-heater unit | ||
| U2 Superior or equal to 10V | ||||
| Yes | ||||
| U3 Superior or equal to 10V | No OK | Verify: The continuity of the plug supply leads | ||
| Yes: End of check |