Checking: Air supply circuit
- Make
- Citroën
- Model
- Jumpy III Factory Workshop Manual
- Year
- 2007–2016
- Section
- Air and fuel supply › Checking: Air supply circuit
Checking: Air supply circuit
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Tooling
| Tools | Reference | Description |
|---|---|---|
| [DA 16] | Manual vacuum pump with adaptors [4530-T.G] |
| [1617-J] | Sealing plugs HDI |
| - | Diagnostic station |
2. Flow chart: Vacuum circuit
2.1. Components
(1) vacuum pump.
(2) Air inlet manifold with integral vacuum reserve.
(3) Remote breather.
(4) Proportional control electrovalve.
(5) Control capsule for the inlet air mixer.
(6) Proportional control electrovalve.
(7) Control capsule for the inlet air cooler by-pass mixer.
(8) Proportional control electrovalve.
(9) Variable geometry control capsule (turbocharger).
(10) Solenoid valve "ON/OFF".
(11) Control capsule for the exhaust gas cooler by-pass flap.
2.2. Link: tyre
"a" Vacuum generation circuit with take-off for the exhaust gas recovery control circuit.
Circuit upstream of the electrovalves:
- "B" Vacuum coupling circuit on the proportional control electrovalves (4) and (6)
- "C" Vacuum coupling circuit on the proportional control electrovalves (8) and "ON/OFF" (10)
Circuit downstream of the electrovalves:
- "D" Control circuit for the inlet air cooler by-pass mixer
- "E" Control circuit for the inlet air mixer
- "F" Control circuit for the variable geometry turbo
- "G" Control circuit for the exhaust gas cooler by-pass flap
- "H" Breather circuit
3. Preliminary operations
CAUTION: Prior to any operation on the vacuum circuit, read the memory of faults and perform the tests as required by the diagnostic tool.
Remove:
- The passenger compartment air inlet manifold
- The engine cover
Check the efficiency of the vacuum pump.
N.B.: If the values are not correct: Replace the component that is faulty.
Remove the protector (12) from the injection system.
Unclip the pipes () (as "j").
Remove the bolts (13).
Take out the heat shield (In accordance with the illustration above).
4. Checking for leaks
CAUTION: The operation on the electrovalves is done with the help of a mirror.
Checks to be performed depending on the types of problems:
- If there is a general failure of the vacuum circuit ("d" + "e" + "f" + "g"), refer to the method for checking the sealing of the vacuum reserve (See below)
- If there is a failure relating to the vacuum circuit controls ("d" + "e" or "f" + "g"), refer to the methods for checking the sealing of the circuit upstream of the electrovalves (See below)
- If it is a localised problem in the vacuum circuit ("d", "e", "f" or "g"), refer to the methods for checking the sealing of the circuit downstream of the electrovalves (See below)
4.1. Vacuum reservoir
Uncouple the vacuum pipes (At "k" and "l").
N.B.: Without removing the electrovalves.
Fit a plug [1617-J] in place of the pipe (at "k").
Connect the manual vacuum pump [DA 16] in place of the pipe (at "l").
Apply a vacuum of 0,7 bar:
- The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
- The vacuum is reached with difficulty, and drops: Recommence the operation upstream of the vacuum reserve until the leak has been identified; Replace the component that is faulty
Couple the vacuum circuit pipes (At "k" and "l").
4.2. Control circuit for the inlet air mixers (Upstream of the electrovalve)
CAUTION: The plug [1617-J] must be in place.
Remove:
Fit a tapered plug [4530-TG] on the pipe exiting the vacuum reserve.
Connect the manual vacuum pump [DA 16] on the second pipe exiting the vacuum reserve.
Apply a vacuum of 0,7 bar:
- The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
- The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty
Remove:
- The plugs [4530-TG], [1617-J]
- The manual pressure vacuum pump [DA 16]
Refit:
4.3. Control circuit for the inlet air mixing (Downstream of the electrovalve)
Uncouple: The turbo air inlet unions (14).
Remove:
CAUTION: Check one inlet air mixer control circuit at a time.
Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.
CAUTION: Check the movement of the flaps (15), with the aid of a mirror and using the diagnostic tool.
Apply a vacuum of 0,5 bar:
- The vacuum is achieved, the flap (15) moves freely: The circuit is sealed, check the electrical components of the system
- The vacuum is reached with difficulty, the flap (15) moves scarcely or not at all; Replace any defective parts
Remove: The manual pressure vacuum pump [DA 16].
Refit:
- The turbo air inlet unions (14)
- Regulated solenoid control valve (6)
- Regulated solenoid control valve (4)
4.4. Control circuit for the turbocharger and the exhaust gas cooler by-pass (Upstream of the electrovalve)
Remove:
Uncouple the vacuum pipe () (as "l").
Fit a plug [1617-J] in place of the pipe (as "l").
Fit a tapered plug [4530-TG] on the pipe exiting the vacuum reserve.
Connect the manual vacuum pump [DA 16] on the second pipe exiting the vacuum reserve.
Apply a vacuum of 0,7 bar:
- The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
- The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty
Remove:
- The plugs [4530-TG]
- The manual pressure vacuum pump [DA 16]
Refit:
4.5. Control circuit for the variable geometry turbo (Downstream of the electrovalve)
Remove: Regulated solenoid control valve (8).
Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.
CAUTION: Check that the control rod (16) on the turbocharger moves, with the aid of a mirror and using the diagnostic tool.
Apply a vacuum of 0,7 bar:
- The vacuum is achieved, the control rod (16) moves freely: The circuit is sealed, check the electrical components of the system
- The vacuum is reached with difficulty, the control rod (16) moves scarcely or not at all: Inspect the condition of the pipe at the electrovalve outlet as well as the variable geometry (turbocharger) control diaphragm (9); Replace any defective parts
Remove: The manual pressure vacuum pump [DA 16].
Refit: Regulated solenoid control valve (8).
4.6. Control circuit for the exhaust gas cooler by-pass flap (Downstream of the electrovalve)
Remove: Regulated solenoid control valve (10).
Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.
CAUTION: Check the movement of the control rod (17) on the EGR valve.
Apply a vacuum of 0,5 bar:
- The vacuum is achieved, the control rod (17) moves freely: The circuit is sealed, check the electrical components of the system
- The vacuum is reached with difficulty, the control rod (17) moves scarcely or not at all: Inspect the condition of the pipe at the electrovalve outlet as well as the control diaphragm of the exhaust gas cooling by-pass flap (11); Replace any defective parts
Remove: The manual pressure vacuum pump [DA 16].
Refit: Regulated solenoid control valve (10).
4.7. Refitting
Refit:
- The heat shield
- The bolts (13)
Clip the pipes (as "j").
Refit the protector (12) on the injection system.
CAUTION: Perform the operations to be carried out following reconnection of the battery.
Reconnect the battery.
CAUTION: Clear the memory of faults; Using the diagnostic equipment.
Refit:
- The engine cover
- The passenger compartment air inlet manifold