Workshop Manuals Factory service & repair Citroën
01 Engine02 Gearbox and clutch03 Transmission and driveshafts04 Suspension05 Steering06 Brakes07 Body - front section08 Body - rear section09 Body - side structure10 Front doors and trim11 Rear doors and trim12 Body - roof and headlining13 Body shell14 Lighting and signalling15 Wipers and washers16 Fascia and interior panels17 Front seats18 Middle row seats19 Rear seats20 Interior trim21 Electrical - general22 Starting and charging23 Wiring harnesses24 Instruments and warning lamps25 Locking, alarm and airbags26 Electrical - driver assistance systems27 Heating, air conditioning and audio
Citroën Jumpy III Factory Workshop Manual (2007-2016)01 · Engine
01 · Engine

Checking: Air supply circuit

Make
Citroën
Model
Jumpy III Factory Workshop Manual
Year
2007–2016
Section
Air and fuel supply › Checking: Air supply circuit
EngineChecking: Air supply circuit

Checking: Air supply circuit

Citroën Jumpy III · Checks · Ref. B1HD013JP0

Applies to: 2.0 dt (DW10CE) or 2.0 dt (DW10CD) or 2.0 HDi 163 PEF

ESSENTIAL: Observe the safety and cleanliness recommendations.

1. Tooling

ToolsReferenceDescription
Figure e5ad01gt
[DA 16]Manual vacuum pump with adaptors [4530-T.G]
Figure e5ag03lt
[1617-J]Sealing plugs HDI
Figure e5ad01ht
-Diagnostic station

2. Flow chart: Vacuum circuit

2.1. Components

Figure b1hdz6np

(1) vacuum pump.

(2) Air inlet manifold with integral vacuum reserve.

(3) Remote breather.

(4) Proportional control electrovalve.

(5) Control capsule for the inlet air mixer.

(6) Proportional control electrovalve.

(7) Control capsule for the inlet air cooler by-pass mixer.

(8) Proportional control electrovalve.

(9) Variable geometry control capsule (turbocharger).

(10) Solenoid valve "ON/OFF".

(11) Control capsule for the exhaust gas cooler by-pass flap.

2.2. Link: tyre

Figure b1hdz6qp

"a" Vacuum generation circuit with take-off for the exhaust gas recovery control circuit.

Circuit upstream of the electrovalves:

  • "B" Vacuum coupling circuit on the proportional control electrovalves (4) and (6)
  • "C" Vacuum coupling circuit on the proportional control electrovalves (8) and "ON/OFF" (10)

Circuit downstream of the electrovalves:

  • "D" Control circuit for the inlet air cooler by-pass mixer
  • "E" Control circuit for the inlet air mixer
  • "F" Control circuit for the variable geometry turbo
  • "G" Control circuit for the exhaust gas cooler by-pass flap
  • "H" Breather circuit

3. Preliminary operations

CAUTION: Prior to any operation on the vacuum circuit, read the memory of faults and perform the tests as required by the diagnostic tool.

Remove:

  • The passenger compartment air inlet manifold
  • The engine cover

Check the efficiency of the vacuum pump.

N.B.: If the values are not correct: Replace the component that is faulty.

Figure b1hdz7gd

Remove the protector (12) from the injection system.

Unclip the pipes () (as "j").

Remove the bolts (13).

Figure b1bd03ed

Take out the heat shield (In accordance with the illustration above).

4. Checking for leaks

CAUTION: The operation on the electrovalves is done with the help of a mirror.

Checks to be performed depending on the types of problems:

  • If there is a general failure of the vacuum circuit ("d" + "e" + "f" + "g"), refer to the method for checking the sealing of the vacuum reserve (See below)
  • If there is a failure relating to the vacuum circuit controls ("d" + "e" or "f" + "g"), refer to the methods for checking the sealing of the circuit upstream of the electrovalves (See below)
  • If it is a localised problem in the vacuum circuit ("d", "e", "f" or "g"), refer to the methods for checking the sealing of the circuit downstream of the electrovalves (See below)

4.1. Vacuum reservoir

Figure b1hdz6yd

Uncouple the vacuum pipes (At "k" and "l").

N.B.: Without removing the electrovalves.

Figure b1hdz9yd

Fit a plug [1617-J] in place of the pipe   (at "k").

Connect the manual vacuum pump [DA 16] in place of the pipe   (at "l").

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Recommence the operation upstream of the vacuum reserve until the leak has been identified; Replace the component that is faulty

Couple the vacuum circuit pipes (At "k" and "l").

4.2. Control circuit for the inlet air mixers (Upstream of the electrovalve)

Figure b1hdz9wd

CAUTION: The plug [1617-J] must be in place.

Remove:

Fit a tapered plug [4530-TG] on the pipe exiting the vacuum reserve.

Connect the manual vacuum pump [DA 16] on the second pipe exiting the vacuum reserve.

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty

Remove:

  • The plugs [4530-TG], [1617-J]
  • The manual pressure vacuum pump [DA 16]

Refit:

4.3. Control circuit for the inlet air mixing (Downstream of the electrovalve)

Figure b1hdz7hd

Uncouple: The turbo air inlet unions (14).

Figure b1hdza3d

Remove:

CAUTION: Check one inlet air mixer control circuit at a time.

Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.

CAUTION: Check the movement of the flaps (15), with the aid of a mirror and using the diagnostic tool.

Apply a vacuum of 0,5 bar:

  • The vacuum is achieved, the flap (15) moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the flap (15) moves scarcely or not at all; Replace any defective parts

Remove: The manual pressure vacuum pump [DA 16].

Refit:

4.4. Control circuit for the turbocharger and the exhaust gas cooler by-pass (Upstream of the electrovalve)

Figure b1hdza4d

Remove:

Uncouple the vacuum pipe () (as "l").

Fit a plug [1617-J] in place of the pipe (as "l").

Figure b1hdza5d

Fit a tapered plug [4530-TG] on the pipe exiting the vacuum reserve.

Connect the manual vacuum pump [DA 16] on the second pipe exiting the vacuum reserve.

Apply a vacuum of 0,7 bar:

  • The vacuum is reached and does not drop: The circuit is sealed, pass to the next check
  • The vacuum is reached with difficulty, and drops: Inspect the condition of the pipes exiting the vacuum reserve; Replace the component that is faulty

Remove:

  • The plugs [4530-TG]
  • The manual pressure vacuum pump [DA 16]

Refit:

4.5. Control circuit for the variable geometry turbo (Downstream of the electrovalve)

Figure b1hdza6d

Remove: Regulated solenoid control valve (8).

Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.

CAUTION: Check that the control rod (16) on the turbocharger moves, with the aid of a mirror and using the diagnostic tool.

Apply a vacuum of 0,7 bar:

  • The vacuum is achieved, the control rod (16) moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the control rod (16) moves scarcely or not at all: Inspect the condition of the pipe at the electrovalve outlet as well as the variable geometry (turbocharger) control diaphragm (9); Replace any defective parts

Remove: The manual pressure vacuum pump [DA 16].

Refit: Regulated solenoid control valve (8).

4.6. Control circuit for the exhaust gas cooler by-pass flap (Downstream of the electrovalve)

Figure b1hdza7d

Remove: Regulated solenoid control valve (10).

Connect the manual vacuum pump [DA 16] on the pipe exiting the electrovalve.

CAUTION: Check the movement of the control rod (17) on the EGR valve.

Apply a vacuum of 0,5 bar:

  • The vacuum is achieved, the control rod (17) moves freely: The circuit is sealed, check the electrical components of the system
  • The vacuum is reached with difficulty, the control rod (17) moves scarcely or not at all: Inspect the condition of the pipe at the electrovalve outlet as well as the control diaphragm of the exhaust gas cooling by-pass flap (11); Replace any defective parts

Remove: The manual pressure vacuum pump [DA 16].

Refit: Regulated solenoid control valve (10).

4.7. Refitting

Refit:

  • The heat shield
  • The bolts (13)

Clip the pipes (as "j").

Refit the protector (12) on the injection system.

CAUTION: Perform the operations to be carried out following reconnection of the battery.

Reconnect the battery.

CAUTION: Clear the memory of faults; Using the diagnostic equipment.

Refit:

  • The engine cover
  • The passenger compartment air inlet manifold

Parts & tools for this job For 2007 Citroën Jumpy

As an Amazon Associate we earn from qualifying purchases.