Removing - Refitting: Oxygen sensor (DV6UC)
- Make
- Citroën
- Model
- Jumpy III Factory Workshop Manual
- Year
- 2007–2016
- Section
- Emission control › Removing - Refitting: Oxygen sensor (DV6UC)
Removing - Refitting: Oxygen sensor (DV6UC)
ESSENTIAL: Observe the safety and cleanliness recommendations.
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. It is strictly prohibited to use solvents or contact greases for cleaning the connectors of the upstream and downstream oxygen sensors.
1. Tooling
| tool | Reference | Designation |
|---|---|---|
| [4386-T] | slit socket 22 mm |
2. Location
(1) Oxygen sensor.
3. Removing
ESSENTIAL: Respect the safety and cleanliness requirements relating to the particle filter.
ESSENTIAL: Wait a minimum of one hour before any operation on the exhaust line and the turbocharger.
Disconnect the ancillaries battery.
Unplug: The connector of the oxygen sensor (1) (at "a").
Unclip and move aside: The oxygen sensor (1) electrical harness (at "b").
Remove the oxygen sensor (1); Using tool [4386-T].
4. Refitting
CAUTION: Adhere to the tightening torques.
Refit the oxygen sensor (1); Using tool [4386-T].
Connect: The connector of the oxygen sensor (1) (at "a").
Clip: The oxygen sensor (1) electrical harness (at "b").
CAUTION: Perform the operations that are required following a reconnection of the ancillaries battery.
Reconnect the ancillaries battery.
5. Check
Start the engine.
Check:
- The absence of exhaust gas leaks
- The operation of the oxygen sensor (1); Using the diagnostic equipment
Stop the engine.