Data - Identification: Exhaust gas recirculation circuit
- Make
- Citroën
- Model
- Xantia Factory Workshop Manual
- Year
- 1993–1998
- Section
- Exhaust › Data - Identification: Exhaust gas recirculation circuit
Data - Identification: Exhaust gas recirculation circuit
The engines with Y or L3 emission standards are equipped with an EGR exhaust gas recycling system.
1. Principles of operation
The EGR exhaust gas recycling system reduces the quantity of nitrogen oxide (N0x) in the exhaust gases.
This reduction is obtained by recycling part of the exhaust gases in the inlet duct.
The conditions for the recycling are a function of the engine water temperature and load.
Composition:
- 1 - Air cleaner
- 2 - Load switch (micro-switch)
- 3 - Temperature switch 60°C
- 4 - Exhaust
- 5 - Recycling valve
- 6 - Vacuum pump
- 7 - Solenoid valve EGR
The load switch is fitted to the injection pump.
The thermal switch is fitted to the water outlet housing (2-way green connector).
The recycling valve is mounted on the exhaust manifold.
The vacuum pump is situated on camshaft end.
The EGR electrovalve pilots the EGR valve.
EGR valve (5) is operated by vacuum pump (6) when electrovalve (7) is activated.
Electrovalve (7) is activated when:
- Engine running
- A coolant temperature above 60 °C
- The engine load is inferior to the limit indicated by injection pump load switch (2)
2. Recycling valve - Data
| engines | make | Reference | Colour identification | Flow at 600 mbars |
| atmospheric diesel | PURFLUX | GR 70 | Green | 27-29 m3/h |
| Diesel turbo | PURFLUX | GR 54 | yellow | 18-22 m3/h |
Parts & tools for this job For 1993 Citroën Xantia
- PARTExhaust gasketSearch: Citroën Xantia 1993 exhaust gasket
- TOOLPenetrating oilSearch: penetrating oil
- TOOLOBD2 scannerSearch: OBD2 scanner