Removing - refitting: Oxygen sensor
- Make
- Citroën
- Model
- Xantia II Factory Workshop Manual
- Year
- 1998–2001
- Section
- Emission control › Removing - refitting: Oxygen sensor
Removing - refitting: Oxygen sensor
CAUTION: For any operation on an oxygen sensor: The oxygen sensor connector must be cleaned dry. It is strictly prohibited to use solvents or contact greases for cleaning the connectors of the upstream and downstream oxygen sensors.
1. Removing
Separate the electrical harness from the clip.
Remove:
- The 2 bolts (3)
- The sheath
- The clip
- The 2 bolts (5)
Disengage wiring harness (7) from the protection shield.
Disconnect the 2 connectors (8).
Remove the oxygen sensor.
2. Refitting
Proceed in the reverse order to removal.
2.1. Electrical connection
Heating function = 2-way connectors - Red.
Signal function = 2-way connectors - White.
2.2. Tightening torque
Tighten the oxygen sensor to 4 m.daN.