Checking-adjusting: Lpg feed pressure
- Make
- Citroën
- Model
- Xantia II Factory Workshop Manual
- Year
- 1998–2001
- Section
- Engine assembly › Checking-adjusting: Lpg feed pressure
Checking-adjusting: Lpg feed pressure
ESSENTIAL: Before any operations Follow the safety instructions.
1. Recommended tools
[1] pressure checker (kit S.1602).
[2] pressure take-off connector (kit S.1602).
[3] hose for removing-fitting pressure connector (kit S.1602).
2. Checking and setting the pressure of the 1st stage
2.1. Preliminary operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Disconnect the solenoid valve (1).
Remove the plug (2).
Fit the tool [2] instead of and in place of the plug (2), Using tool [3].
Tighten the tool [2].
2.2. Checking-adjusting
Connect output "a" of tool [1] to tool [2].
Connect output "b" of tool [1] to take-off (3).
Reconnect the electrovalve (1).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Change to LPG mode.
Accelerate the engine: Up to 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 1400 ± 50 mb
- New evaporator control valve: 1450 ± 50 mb
Adjust the value of pressure by adjusting the screw (4) (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
2.3. Additional operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Disconnect the solenoid valve (1).
Remove:
- The tool [1]
- The tool [2] Using tool [3]
Refit and tighten the plug (2).
3. Checking and setting the pressure of the 2nd stage
3.1. Preliminary operations
Slacken the 2 fixing screws of the distributor (5).
Raise the distributor (5).
Remove the plug (6).
Fit the tool [2], Using tool [3].
Tighten the tool [2].
3.2. Checking-adjusting
Connect output "a" of tool [1] to tool [2].
Connect output "b" of tool [1] to take-off (5).
Reconnect the electrovalve (1).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Change to LPG mode.
Accelerate the engine: Up to 3000 rpm.
Return to idle.
Wait 30 seconds.
Read the pressure Using tool [1].
Adjustment values:
- Evaporator control valve which has already been used: 960 ± 10 mb
- New evaporator control valve: 970 ± 10 mb
Adjust the value of pressure by adjusting the screw (7) (if necessary).
N.B.: Tighten the screw to increase the pressure. Slacken the screw to reduce the pressure.
3.3. Additional operations
ESSENTIAL: Partially drain the LPG supply circuit (see the relevant operation).
Remove:
- The tool [1]
- The tool [2] Using tool [3]
Refit and tighten the plug (6).
Fit the distributor (5).
Tighten the 2 mounting bolts of the distributor (5).
Activate the lpg feed circuit (see the relevant operation).
Start the engine.
Check that the lpg mode operates correctly.
Parts & tools for this job For 1998 Citroën Xantia
- PARTEngine gasket setSearch: Citroën Xantia 1998 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.