Check: Exhaust gas recirculation circuit
- Make
- Citroën
- Model
- Xsara Factory Workshop Manual
- Year
- 1997–2000
- Section
- Emission control › Check: Exhaust gas recirculation circuit
Check: Exhaust gas recirculation circuit
ESSENTIAL: Observe the safety and cleanliness recommendations.
1. Recommended tools
[1] vacuum-pressure manual pump FACOM DA 16.
2. Check
2.1. EGR valve
Connect the tool [1] to the valve union (1).
Apply a vacuum of approximately 0,6 bar several times in succession in order to activate the shaft "a".
When the vacuum is suddenly cut off, the valve should click as it returns to its seat.
2.2. Recycling regulation electrovalve (EGR)
A vacuum check is to be carried out between the electrovalve (2) and the EGR valve (1).
Connect the tool [1] between the electrovalve (2) and the valve (1).
Compare the values read with those of the table below.
| Engine speed | Vacuum value |
|---|---|
| 780 rpm | 0,5 bar |
| 2500 rpm | 0 bar |
Parts & tools for this job For 1997 Citroën Xsara