1. Valve clearances
Operating clearance in mm:
- Inlet valve: 0,15 mm
- Exhaust valve: 0,30 mm
- Tolerance: ± 0,08 mm
1.1. Method of checking
| - | First method | - |
|---|---|---|
| Fully open | Check | Check |
| Exhaust valve | Inlet valve | Exhaust valve |
| 1 | 3 | 4 |
| 3 | 4 | 2 |
| 4 | 2 | 1 |
| 2 | 1 | 3 |
For each valve note the values recorded for the clearances.
| - | Second method | - |
|---|---|---|
| - | Check | Check |
| Inlet valve | Exhaust valve | |
| Position the valves of cylinder N°1 on the rock | 4-3 | 4-2 |
| Position the valves of cylinder N°4 on the rock | 1-2 | 1-3 |
For each valve note the values recorded for the clearances.
1.2. Valve clearance adjustment
(1) Thrust pad.
(2) Adjustment shim.
Clearance J is measured with the engine cold.
If the clearance measurements J are not correct, carry out the following operations:
- Measure the thickness "E2" of the adjustment shim (2)
- Determine the thickness of adjustment shims (2) to be fitted by referring to the example (column A or B)
| Example | ||
|---|---|---|
| - | A | B |
| Operating clearance | 0,15 mm | 0,30 mm |
| Clearance measured | 0,075 mm | 0,40 mm |
| Difference | -0,075 mm | +0,10 mm |
| E mm | 2,95 mm | 2,85 mm |
| Shims to be fitted | 2,875 mm | 2,95 mm |
| Clearance obtained | 0,15 mm | 0,30 mm |
Key:
- A: Inlet valve
- B: Exhaust valve
CAUTION: Observe the direction of fitting of the adjustment washers.
N.B.: Area "a" can be identified by its shing surface.
2. Valve timing chart
Diagram with a theoretical valve clearance of 0,8 mm.
| - | - | Prior to 09/86 | From 10/86 |
| Engine legislative type | - | 161A / 162 | A9A / D8A / D8B / D8C / D9A / D9B / D9D / DHX / DHY / DJY / DJZ |
| Inlet valve | AOA | 4°30’" | -4° |
| RFA | 28°30’" | 35° | |
| Exhaust valve | AOE | 43° | 43° |
| RFE | 0° | 0° |
AOA = Before Top Dead Centre.
RFA = After Bottom Dead Centre.
AOE = Before Bottom Dead Centre.
RFE = After Top Dead Centre.
| - | Data | - | - |
|---|---|---|---|
| Engine legislative type | - | AJZ / A8A / A8B | DHV / DHW |
| Inlet valve | AOA | -4°30’" | 11°30’" |
| RFA | 20°30’" | 20° | |
| Exhaust valve | AOE | 39°15’" | 39° |
| RFE | -3°45’" | 4° |
AOA = Before Top Dead Centre.
RFA = After Bottom Dead Centre.
AOE = Before Bottom Dead Centre.
RFE = After Top Dead Centre.
Parts & tools for this job For 1997 Citroën Xsara
- PARTEngine gasket setSearch: Citroën Xsara 1997 engine gasket set
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLFeeler gauge setSearch: feeler gauge set
As an Amazon Associate we earn from qualifying purchases.