Modification: Coded anti-start
- Make
- Citroën
- Model
- ZX Factory Workshop Manual
- Year
- 1991–1998
- Section
- Dashboard › Modification: Coded anti-start
Modification: Coded anti-start
Applicable: 05/1995.
Purpose of the modification:
- Improve the anti-theft protection
- Comply with the recommendations of the various insurance companies
1. Presentation
1.1. Former arrangement
There exist 2 generations of "ADC" keyboards.
1.2. "A" version
With specific key D/N:
- Deferred locking mode
- Neutral mode
1.3. "B" version (1995 (*) M.Y. for certain countries)
Keys 0 and D/N deleted (and replaced by a dash).
Modes no longer present:
- Deferred locking mode
- Neutral mode
N.B.: (*) Germany.
1.4. New arrangement
Introduction of a new key S, Service mode.
1.5. As compared with version "a"
New mode: Service mode.
Key D/N deleted.
1.6. As compared with version "b"
New mode: Service mode.
Addition of figure 0 (greater number of combinations).
2. Operating procedure
2.1. Starting the vehicle
Enter either the user code or the service code.
2.2. Changing the code (press "C")
No modification.
2.3. Deferred locking mode
No longer present.
2.4. Neutral mode
No longer present.
2.5. Service mode
Makes it possible to hand your vehicle to somebody without revealing your personal code.
2.6. Operating procedure
Switch on the ignition.
Enter the user’s code (4-figure code).
Press button S: Audible beep (1).
Introduce the service code (4-figure code).
Press button S: The green LED flashes 6 times with 6 bleeps (2).
Switch off the ignition: The red LED remains on, accompanied by 4 audible beeps (for 10 seconds) (3).
To cancel the service mode: Switch on the ignition. Enter the user’s code.
N.B.: (1).
No audible beep:
- Service mode is not authorised
- To enter service mode, the security code must have been used at least 2 times
- Close the vehicle
- Before closing the bonnet check that the opening control and the lock are operating correctly
N.B.: (2).
Long audible beep period:
- Service mode is not authorised
- Enter code C 0 C The green LED flashes 4 times with 4 bleeps
- Switch off the ignition
- Before closing the bonnet check that the opening control and the lock are operating correctly
N.B.: (3) Occurs each time the ignition is switched off and as long as the service mode is activated.
3. Description
3.1. Coded engine immobiliser keypad
Identification: Label bearing a PSA No., stuck to the side face.
The new "ADC" keyboard has 3 storage memories:
- Former user’s code
- New user’s code
- Service code
Each time the service code is introduced, the user’s code in memory in the key board is delivered to unlock the injection ECU.
In the service mode:
- The code changing procedure is not operational (press "C")
- The locking conditions after opening the doors are unchanged
The "ADC" keyboard is provided with an autodiagnostic system, connected to the diagnostic socket.
The autodiagnosis device allows checking:
- The re-energising relay
- The communication with the injection ECU
- The keys of "ADC" keyboard
The new keyboard ref. 96 200 527 ZL will be gradually replaced with a keyboard ref. 96 255 838 ZL.
New "ADC" keyboard 96 255 838 ZL:
- If 3 erroneous codes have been introduced in succession,, The "ADC" keyboard locks for 30 minutes (instead of 1 min.)
- The code 0000 becomes a user code
CAUTION: To unlock the "ADC" keyboard: Wait for at least 30 minutes (instead of 1 min.). Switch on the ignition for 1 minute(s) Before re-entering the code.
3.2. Injection ECUs
Applicable: 06/1995.
It is no longer possible to neutralise the coded anti-theft function, of the injection ECU.
The code 0000 becomes a user code.
If 3 erroneous codes have been introduced in succession,, The injectin ECU locks for 1 minute.
CAUTION: To unlock the injection ECU: Switch on the ignition for 1 minute(s).
Parts & tools for this job For 1991 Citroën ZX
- TOOLTorque wrenchSearch: 3/8 inch torque wrench
- TOOLSocket setSearch: socket set metric
- BOOKHaynes manualSearch: Haynes manual Citroën ZX
As an Amazon Associate we earn from qualifying purchases.