Starter Motor: Description and Operation

Wound field starter motors have pole pieces, arranged around the armature, which are energized by wound field coils.
Enclosed shift lever cranking motors have the shift lever mechanism and the solenoid plunger enclosed in the drive housing, protecting them from
exposure to dirt, icy conditions, and splashes.
In the basic circuit, solenoid windings are energized when the switch is closed. The resulting plunger and shift lever movement causes the pinion to
engage the engine flywheel ring gear. The solenoid main contacts close. Cranking then takes place.
When the engine starts, pinion overrun protects the armature from excessive speed until the switch is opened, at which time the return spring causes the
pinion to disengage. To prevent excessive overrun, the switch should be released immediately after the engine starts.