Hose/Line HVAC: Service and Repair
A/C High-Pressure Line

A/C HIGH-PRESSURE LINE

REMOVAL PROCEDURE

1. Disconnect the negative battery cable.

2. Recover the refrigerant. Refer to "Discharging, Adding Oil, Evacuating, and Charging Procedures for A/C System".

3. Remove the air cleaner housing bolts and the air filter housing assembly.

4. Remove the bolt that secures the liquid evaporator pipe connector block to the liquid condenser connector block and separate the pipes.

Handling of Refrigerant Lines and Fittings|Page 446 > < Handling of Refrigerant Lines and Fittings