12.

Remove required wedge and circuit indicated in Figure 2 diagram, and insert this circuit into the supplied insulator as shown in the diagram.

13.

Insert the bare terminal from the supplied wiring assembly into the vacated cavity in the bulkhead as shown in the diagram.

14.

Install the wedges and connect the bulkhead.

15.

Install the steering column cover, instrument cluster bezel, radio, glove box and heater and A/C controls.

16.

Connect the negative battery cable and verify the system for proper operation.

POLICY:
Reimbursable within the provisions of the warranty.

TIME ALLOWANCE
Labor Operation No.    24-50-17-91 ..........................................................................................................................................................................  0.9 Hrs.

FAILURE CODE:
58 - Internal defect