The following information describes the different mode sensor positions:

-

4LO TARGET REGION - The position shall be considered 4LO if the voltage is greater than or equal to encoder_4LO_min Volts and it is also
less than or equal to encoder_4LO_max Volts.

-

4LO SHIFT LIMIT - During Phase 2 and Phase 3 shifting, shifts may become unidirectional when a voltage is less than or equal to
encoder_4LO_min Volts has been reached.

-

4LOCK TARGET REGION - The position shall be considered 4LOCK if the voltage is greater than or equal to encoder_4LOCK_min Volts and it
is also less than or equal to encoder_4LOCK_max Volts.

-

NEUTRAL TARGET REGION - The position shall be considered NEUTRAL if the voltage is greater than or equal to encoder_Neutral_min
Volts and it is also less than or equal to encoder_Neutral_max Volts.

-

AWD TARGET REGION - The position shall be considered AWD if the voltage is greater than or equal to encoder_AWD_min Volts and it is
also less than or equal to encoder_AWD_max Volts.

-

AWD SHIFT LIMIT - During Phase 2 and Phase 3 shifting, shifts may become unidirectional when a voltage is greater than or equal to
encoder_AWD_min Volts has been reached.

The mode sensor position will be considered invalid by the FCM if the voltage is greater than or equal to encoder_High_Range_Limit Volts or if it is
less than or equal to encoder_Low_Range_Limit Volts.

Refer to MODE SENSOR VOLTAGES - NV244 table for the mode sensor voltages.

Mode Sensor Voltages - NV244