dodge Workshop Repair Guides

Dodge Workshop Service and Repair Manuals

Coupler HVAC > < A/C Bi-Level Mode - Unbalanced Vent Air Flow|Page 5756
Page 2
background image

INSTALLATION
1. Connect the temperature control cable core end to the temperature control lever on the back of the heater-A/C control.
2. Connect the temperature control cable housing flag retainer to the receptacle on the back of the heater-A/C control.
3. Plug in the vacuum harness connector and install the two stamped nuts to secure the connector to the back of the heater-A/C control.
4. Plug the wire harness connector into the back of the heater-A/C control.
5. Reinstall the wire harness retainer to the side of the heater-A/C control.
6. Position the heater-A/C control in the instrument panel and secure it with four screws. Tighten the screws to 2.2 N.m (20 in. lbs.).
7. Reinstall the cluster bezel to the instrument panel. Refer to:  Instrument Panel, Gauges, Warning Indicators, Instrument Cluster/Carrier

Service and Repair, Instrument Cluster Bezel Replacement, See: Instrument Panel, Gauges and Warning Indicators/Instrument Cluster /
Carrier/Service and Repair/Procedures/Instrument Cluster Bezel Replacement

8. Connect the battery negative cable.
9. Adjust the temperature control cable. See Temperature Control Cable in the Adjustments for the procedures.

Coupler HVAC > < A/C Bi-Level Mode - Unbalanced Vent Air Flow|Page 5756