eagle Workshop Repair Guides

Eagle Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 3913 > < Diagram Information and Instructions|Page 3911
Page 1
background image

Canister Purge Solenoid: Testing and Inspection

Evaporative Emission Purge Solenoid Harness Inspection

HARNESS INSPECTION

Evaporative Emission Purge Solenoid

SCAN TOOL INSPECTION

SOLENOID INSPECTION

1. Disconnect and mark the black and red-striped vacuum hoses from the solenoids so they can be reconnected at the original positions.
2. Disconnect the harness connector.

Fig. 1 Purge Control Solenoid Valve Inspection (Operation)

3. Connect a hand vacuum pump to nipple A of the solenoid valve (as indicated in illustration).
4. Check airtightness when voltage is supplied and not supplied as indicated.

Diagram Information and Instructions|Page 3913 > < Diagram Information and Instructions|Page 3911