Accumulator HVAC: Service and Repair

Suction Accumlator

Material

Removal and Installation

NOTE:  Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.

2. Disconnect the spring lock couplings.

-

Discard the O-ring seals.

3. Disconnect the low-charge protection switch electrical connector.

WARNING:  If equipped with fire suppression system, depower the system.

4. Raise the vehicle.

5. Remove the bolts and the suction accumulator.

WARNING:  If equipped with fire suppression system, repower the system.

6. To install, reverse the removal procedure. If equipped with fire suppression system, repower the system.

-

Install new O-ring seals lubricated in clean PAG oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.

Air Conditioning Switch > < Accumulator HVAC|Description and Operation