background image

5. Disconnect the A/C fitting and remove the compressor manifold and tube assembly.

-

Discard the O-ring seals.

6. To install, reverse the removal procedure.

-

Install new O-ring seals lubricated in clean PAG oil.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.