3. Install the deluxe injector loop kit between the high-pressure and low-pressure service gauge port valves.

4. CAUTION:  Make sure all tools and hoses are clear of the engine cooling fan and drive belt before starting the engine. 

Start the engine.

5. Open the high-pressure service valve.

6. Open the deluxe injector loop kit valves and inject the fluorescent dye into the refrigerant system.

7. Close the high-pressure service valve to allow the pressure inside the deluxe injector loop kit to equalize with the suction side of the refrigerant

system.

8. NOTE:  Close the valves on the deluxe injector loop kit while the A/C compressor is operating. 