4. NOTE:  If there is any oil residue, clean both connecting ports and the inside surface of the charge-air-cooler pipe to prevent the pipe from

blowing off.

Loosen the clamps and remove the charge-air-cooler pipe.
^

Tighten to 12 Nm (9 ft. lbs).

5. Disconnect the oil level indicator and tube from the stator.

6. Disconnect the glow plug wire retainer, remove the nut and position the oil level indicator and tube aside.

^

Tighten to 8 Nm (71 inch lbs).

7. Disconnect the glow plug module electrical connectors.

8. Disconnect the exhaust pressure sensor electrical connector and pushpin retainer.