ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Timing Cover|Installation|Page 1778 > < Timing Cover|Installation|Page 1776
Page 8
background image

16. Connect the CKP sensor electrical connector.

17. Connect the A/C compressor electrical connector.

18. Position the bracket, connect the tubes and install the nut.

^

Tighten to 30 Nm (22 lb-ft).

19. Connect the wiring harness to the bracket.

Timing Cover|Installation|Page 1778 > < Timing Cover|Installation|Page 1776