ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3720 > < Initial Inspection and Diagnostic Overview|Page 3718
Page 2
background image

3. Lift up on the End Play Checking Tool as far as it will move and note the dial indicator reading.

-

If the reading exceeds end play limits, replace the torque converter.

4. Remove the dial indicator and tool.

Leakage Checks

Special Tools

1. Clean the outside surface of the torque converter.

2. Install the Torque Converter Leak Check Tool and Gasket into the converter hub.

3. Install the torque converter with the installed leak check tool into the Arbor press.