Page 3
background image

Secure the press. Apply enough force from the press to seal the tool into the torque converter.

WARNING:  ALWAYS FOLLOW PROPER SAFETY PROCEDURES WHILE USING THE PRESS.

4. Apply air pressure to the valve on the leak check tool.

NOTE:  Use clean, dry shop air.

5. With air pressure applied to the valve, inspect for leaks at the converter hub, the seams and the studs. A soap bubble solution can be applied

around those areas to aid in the diagnosis. If any leaks are present, replace the converter.

6. Remove the air hose. Release the pressure, and then slowly release the press. Remove the converter. Remove the tool.

One-Way Clutch Check