ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Procedures|Page 1904 > < Procedures|Page 1902
Page 22
background image

Camshaft Phaser and Sprocket - RH

Removal

NOTICE: This procedure must be followed exactly or damage to the valves and pistons will result.

1. Position the crankshaft damper spoke at the 12 o'clock position and the timing mark indentation at the 1 o'clock position.

2. Remove the RH valve cover. For additional information, refer to Valve Cover - RH  See: Cylinder Head Assembly/Valve Cover/Service and

Repair/Valve Cover - RH.

3. NOTICE: Damage to the camshaft phaser and sprocket assembly will occur if mishandled or used as a lifting or leveraging device.

NOTICE: Only use hand tools to remove the camshaft phaser and sprocket assembly or damage may occur to the camshaft or camshaft
phaser and sprocket.

Loosen and backoff the RH camshaft phaser and sprocket bolt one full turn.

4. Disconnect the RH Camshaft Position (CMP) sensor electrical connector.

5. Remove the bolt and the RH CMP sensor.

Procedures|Page 1904 > < Procedures|Page 1902