Expansion Block/Orifice Tube: Service and Repair
Thermostatic Expansion Valve - Auxiliary Climate Control

Thermostatic Expansion Valve - Expedition, Navigator

Removal and Installation

1. Recover the refrigerant.

2. Remove the RH quarter trim panel.

3. Remove the Thermostatic Expansion Valve (TXV) fitting bolt and disconnect the fitting.

-

Discard the O-ring seals.

4. Remove the 2 TXV bolts.

5. Remove the TXV.

-

Discard the O-ring seals.

6. To install, reverse the removal procedure.

-

Install new O-ring seals.

-

Lubricate the refrigerant system with the correct amount of clean PAG oil.

7. Evacuate, leak test and charge the refrigerant system.