ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3020 > < Initial Inspection and Diagnostic Overview|Page 3018
Page 48
background image

identify the possible causes of the circuit short. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
T2 CHECK THE APIM GROUND CIRCUITS FOR AN OPEN

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the APIM C3342-37, circuit GD114 (BK/BU), harness side and ground; and between the APIM C3342-38, circuit
GD114 (BK/BU), harness side and ground.

-

Are the resistances less than 5 ohms?

Yes

GO to T3.

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
T3 CHECK THE HS-CAN CIRCUITS BETWEEN THE APIM AND THE DLC FOR AN OPEN

-

Measure the resistance between the APIM C3342-53, circuit VDB04 (WH/BU), harness side and the DLC C251-6, circuit VDB04 (WH/BU),
harness side.

-

Measure the resistance between the APIM C3342-54, circuit VDB05 (WH), harness side and the DLC C251-14, circuit VDB05 (WH), harness
side.

-

Are the resistances less than 5 ohms?

Yes

GO to T4.

No

REPAIR the circuit in question. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------

Initial Inspection and Diagnostic Overview|Page 3020 > < Initial Inspection and Diagnostic Overview|Page 3018