14. Correctly support the instrument panel and remove the RH instrument panel support bolts to allow the instrument panel to be pulled away from the

dash panel.

CAUTION:
-

Be sure the instrument panel is properly supported to avoid possible damage to the instrument panel wiring and components.

-

To avoid damage to the instrument panel wiring or components, do not use excessive force when moving the instrument panel away from the
dash panel.

NOTE:  The instrument panel may be supported by installing threaded rods or equivalent, with the same diameter and thread pitch, in place of the
instrument panel support bolts.

15. Position aside the floor airflow vacuum control motor.

-

Remove the screws.

-

Disconnect the vacuum connector.

-

Position aside the floor airflow vacuum control motor.

16. Remove the RH temperature blend door actuator. 

1

Remove the screws.

2

Disconnect the electrical connector.

3

Remove the RH temperature blend door actuator.

INSTALLATION

1. To install, reverse the removal procedure.
2. Reactivate the supplemental restraints system (SRS).

Recirculation Air Duct Door

REMOVAL

1. Remove the recirculation air duct.

Main Climate Control|Page 9547 > < Main Climate Control|Page 9545