J1-J3

Normal Operation

The DSM communicates with the diagnostic tool through the medium speed controller area network (CAN), circuits VDB06 (GY/OG) and VDB07
(VT/OG). Check the medium speed CAN circuits between the DSM C341c and the data link connector (DLC) C251. The total resistance values must
not be more than 5 ohms. If the resistance is more than 5 ohms there is an open in one of the high speed CAN circuits, damage to the DLC C251,
damage to the DSM C341c, or a problem in an in-line connector.

Possible Causes

-

medium speed CAN data plus circuit VDB06 (GY/OG) open