ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2857 > < Initial Inspection and Diagnostic Overview|Page 2855
Page 68
background image

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new IC. REFER to Instrument Panel, Gauges and Warning Indicators. CONNECT all modules. CLEAR the DTCs. REPEAT the network
test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S50 CHECK FOR CORRECT ACM OPERATION

-

Disconnect all the ACM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the ACM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new ACM. REFER to Accessories and Optional Equipment. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the
scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S51 CHECK FOR CORRECT HVAC MODULE OPERATION

-

Disconnect all the HVAC module connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the HVAC module connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new HVAC module. CONNECT all modules. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CONNECT all modules. CLEAR
the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
S52 CHECK FOR CORRECT RETM OPERATION

-

Disconnect the RETM connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the RETM connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

Initial Inspection and Diagnostic Overview|Page 2857 > < Initial Inspection and Diagnostic Overview|Page 2855