ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3170 > < Initial Inspection and Diagnostic Overview|Page 3168
Page 53
background image

-

Fuse

-

Wiring, terminals or connectors

-

PRB module

 

PINPOINT TEST Q: THE PRB MODULE DOES NOT RESPOND TO THE SCAN TOOL

NOTICE:  Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the
connector.

NOTE:  Failure to disconnect the battery when instructed will result in false resistance readings. Refer to Battery.

-------------------------------------------------
Q1 CHECK THE PRB MODULE VOLTAGE SUPPLY CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: PRB Module C3313b.

-

Ignition ON.

-

Measure the voltage between the PRB module C3313b-1, circuit SBB11 (BU/RD), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to Q2.

No

VERIFY the Battery Junction Box (BJB) fuse 11 (30A) is OK. If OK, REPAIR the circuit. If not OK, REFER to the Wiring Diagrams to identify the
possible causes of the circuit short. CLEAR the DTCs. REPEAT the network test with the scan tool.  See: Diagrams/Electrical Diagrams/Diagrams By
Number

-------------------------------------------------
Q2 CHECK THE PRB MODULE GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the PRB module C3313b-4, circuit GD139 (BK/YE), harness side and ground.

-

Is the resistance less than 5 ohms?

Yes

Initial Inspection and Diagnostic Overview|Page 3170 > < Initial Inspection and Diagnostic Overview|Page 3168