ford Workshop Repair Guides

Ford F 150 4WD V8-46L Workshop Service and Auto Repair Manuals

Initial Inspection and Diagnostic Overview|Page 3179 > < Initial Inspection and Diagnostic Overview|Page 3177
Page 62
background image

-

Ignition ON.

-

Measure the voltage between the ILCM C3498-7, circuit CBX07 (GN/RD), harness side and ground.

-

Is the voltage greater than 10 volts?

Yes

GO to T2.

No

VERIFY the Smart Junction Box (SJB) fuse 14 (10A) is OK. If OK, REPAIR the circuit in question. If not OK, REFER to the Wiring Diagrams to
identify the possible causes of the circuit short. CLEAR the DTCs. REPEAT the network test with the scan tool.  See: Diagrams/Electrical
Diagrams/Diagrams By Number

-------------------------------------------------
T2 CHECK THE ILCM GROUND CIRCUIT FOR AN OPEN

 

-

Ignition OFF.

-

Disconnect: Negative Battery Cable.

-

Measure the resistance between the ILCM C3498-10, circuit GD908 (BK), harness side and ground.

Initial Inspection and Diagnostic Overview|Page 3179 > < Initial Inspection and Diagnostic Overview|Page 3177