Fuel System - General Information - Liquified Petroleum Gas (LPG) - Fuel System Service Precautions Focus 1999 (08/1998-12/2004)
General Procedures

  1. WARNING:
    WARNING:Do not modify the system configuration or components, or install components not specially designed for use with alternative fuels. Ford Motor Company Ltd has specially designed the materials, components and system configuration for alternative fuel vehicles, and each particular system is precisely calibrated for efficient operation. The use of incorrect parts or materials can produce an untested configuration that could result in fire, or cause engine damage. Failure to follow these instructions may result in personal injury.
    WARNING:
    WARNING:Fuel supply lines will remain pressurized after shutdown. When servicing fuel related components, do not smoke or carry lighted tobacco or any open flame of any type. Flammable gases may be present and ignite. Failure to follow these instructions may result in personal injury.
    WARNING:
    WARNING:Eye, hand and ear protection are required to be worn during depressurizing or removal and installation of fuel system components. Failure to follow this instruction may result in personal injury.
    WARNING:
    WARNING:Always ground the vehicle and alternative fuel system. High pressure gas escaping can cause static electricity buildup and subsequent sparking. Failure to follow this instruction may result in personal injury.
    WARNING:
    WARNING:Never attempt to tighten or adjust fittings while system is pressurized. Failure to follow this instruction may result in personal injury.
    WARNING:
    WARNING:All gas lines must be installed prior to reconnecting the battery. Failure to follow this instruction may result in personal injury.
    WARNING:
    WARNING:The fuel tank and lines must be evacuated before the fuel line quick release couplings and other fuel line connectors can be disconnected. Failure to follow this instruction may result in personal injury.
    CAUTION:
    CAUTION:If the alternative fuel system is being disconnected for an extended length of time, cover all open hose fittings and electrical connections to avoid contamination.

Fuel Tank Evacuation > < Fuel System