ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Air Door, HVAC > < Accumulator HVAC|Service Precautions|Page 7136
Page 1
background image

Accumulator HVAC: Service and Repair

SUCTION ACCUMULATOR

REMOVAL

CAUTION:  Refrigerant compressor oil (mineral oil) F73Z-19577-AA (Motorcraft YN-9-A) should be used to lubricate R-134a refrigerant
system O-ring seals only and should not be added to the R-134a refrigerant system as an A/C compressor lubricant. PAG refrigerant
compressor oil F7AZ-19D589-DA (Motorcraft YN-12-C) or equivalent meeting Ford specification WSH-M1C231-B only should be used as an
A/C compressor lubricant.

NOTE:

-

New O-ring seals, lubricated in clean mineral oil, must be installed before reconnecting any A/C fitting that has been disconnected.

-

Installation of a new suction accumulator is not required when repairing the air conditioning system, except when there is physical evidence of
system contamination from a failed A/C compressor or damage to the suction accumulator.

1. Recover the refrigerant.

2. Remove the parts in the order indicated in the illustration and table.

INSTALLATION

1. To install, reverse the removal procedure.
2. Lubricate the refrigerant system with the correct amount of clean PAG oil.
3. Evacuate, leak test and charge the refrigerant system.

Air Door, HVAC > < Accumulator HVAC|Service Precautions|Page 7136