Install the RCM.
-

Install the remaining bolt.
-

Tighten to 12 Nm (9 lb-ft).

-

Connect the small RCM electrical connector.

3. Make sure the large RCM connector position assurance lever is in the full release position before attempting to connect the connector.

4. CAUTION:  Placing the large RCM electrical wiring connector into the RCM on an angle, can cause bad electrical connections and

damaged components.

NOTE:  The RCM has been removed for clarity.

Position the large RCM electrical connector into the RCM.

-

CAUTION:  Do not push the connector to where the lever pivots and seats itself. Light pressure is needed to get the connector into
position on the RCM, before using the lever to fully seat the connector.

With the large RCM electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and slight
resistance is felt.