In-vehicle Repair Removal | -
Detach the positive crankcase ventilation (PCV) hose from the power supply rail. | | -
Disconnect the camshaft position (CMP) sensor electrical connector. | | -
Disconnect the power supply rail from the fuel injectors. | Installation | -
NOTE:Install a new valve cover gasket. Install the valve cover. - Tighten the nuts and bolts in the sequence shown in two stages.
- Stage 1: Tighten nuts and bolts 1 through 15 to 3 Nm.
- Stage 2: Tighten nuts and bolts 1 through 15 to 9 Nm
| | -
Connect the CMP sensor electrical connector. | | -
Connect the power supply rail to the fuel injectors. | | -
Attach the PCV hose to the power supply rail. | | |