Removal and Installation
Generator - 1.8L Endura-DE (Kent) Diesel
Generator and Regulator - Generator—1.8L Endura-DE (Kent) Diesel
Ikon 1999 (01/2000-)
Removal and Installation
Removal
Disconnect the battery ground cable. For additional information, refer to Section
414-01 Battery, Mounting and Cables
.
Remove the accessory drive belt tensioner. For additional information, refer to Section
303-05 Accessory Drive
.
Detach the air conditioning (A/C) compressor and secure it to one side.
Disconnect the generator electrical connector.
Disconnect the generator electrical connector.
Remove the generator lower retaining bolts.
Remove the generator.
Installation
CAUTION:
Make sure the generator is tightened using the following graphical sequence, otherwise premature failure of the mounting bracket may occur.
To install, reverse the removal procedure.