ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Valve Stem Seals > < Variable Valve Timing (VVT) Unit
Engine - 1.6L Duratec-16V Ti-VCT (Sigma) - Valve Cover Mondeo 2007.5 (02/2007-)
Removal and Installation

Removal

NOTE:
NOTE:Removal steps in this procedure may contain installation details.
  1. Refer to: Battery Disconnect and Connect (414-01 Battery, Mounting and Cables, General Procedures).

Installation

  1. Install all components in reverse order.

  1. NOTE:
    NOTE:The gasket is to be reused unless damaged.
    1. Screw in bolt 1 by 3 - 4 turns.
    1. Bolts 2 - 13.
      Torque: 9 Nm
    1. Bolt 1.
      Torque: 9 Nm