Page 30
background image

-

Is the vehicle equipped with a SDARS module?

Yes

GO to I19.

No

GO to I20.

-------------------------------------------------
I19 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE SDARS MODULE
DISCONNECTED

-

Disconnect: SDARS Module C4344.

-

Measure the resistance between the DLC C251-3, circuit 1847 (WH/OG), harness side and ground; and between the DLC C251-11, circuit 1848
(PK/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT all modules. CONNECT the negative battery cable. GO to I23.

No

GO to I20.

-------------------------------------------------
I20 CHECK THE MS-CAN (+) AND MS-CAN (-) CIRCUITS FOR A SHORT TO GROUND WITH THE ACM DISCONNECTED

-

Disconnect: SJB C290a.

-

Measure the resistance between the DLC C251-3, circuit 1847 (WH/OG), harness side and ground; and between the DLC C251-11, circuit 1848
(PK/OG), harness side and ground.

-

Are the resistances greater than 1,000 ohms?

Yes

CONNECT all modules. CONNECT the negative battery cable. GO to I24.

No

REPAIR the circuit. CONNECT all modules. CONNECT the negative battery cable. CLEAR the DTCs. REPEAT the network test with the scan tool.

-------------------------------------------------
I21 CHECK FOR CORRECT SJB OPERATION

-

Disconnect all the SJB connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all the SJB connectors and make sure they seat correctly.