ford Workshop Repair Guides

Ford Workshop Service and Repair Manuals

Initial Inspection and Diagnostic Overview|Page 2548 > < Initial Inspection and Diagnostic Overview|Page 2546
Page 31
background image

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SJB. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
I22 CHECK FOR CORRECT IC OPERATION

-

Disconnect the IC connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the IC connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new IC. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
I23 CHECK FOR CORRECT SDARS MODULE OPERATION

-

Disconnect the SDARS module connector.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect the SDARS module connector and make sure it seats correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Yes

INSTALL a new SDARS module. CLEAR the DTCs. REPEAT the network test with the scan tool.

No

The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the
network test with the scan tool.

-------------------------------------------------
I24 CHECK FOR CORRECT ACM OPERATION

-

Disconnect all of the ACM connectors.

-

Check for:
-

corrosion

-

damaged pins

-

pushed-out pins

-

Connect all of the ACM connectors and make sure they seat correctly.

-

Operate the system and verify the concern is still present.

-

Is the concern still present?

Initial Inspection and Diagnostic Overview|Page 2548 > < Initial Inspection and Diagnostic Overview|Page 2546